Typical Filtered Volumes


Typical Filtered Volumes – Aqueous Solutions – Single Layer Membrane

Filter Size Filter Area Volume to be Filtered
D50C 15.9 cm2 Thru-Put: 50 ml to 550 ml
D65R 26 cm2 Thru-Put: 75 ml to 750 ml
D90R 60 cm2 Thru-Put: 100 ml to 3,000 ml
JKP 260 cm2 Thru-Put: 300 ml to 4 Liters
MKP 500 cm2 Thru-Put: 1.5 Liters to 60 Liters
SKL-“H" Size 680 cm2 Thru-Put: 10 Liters to 60 Liters
SKL-“S" Size 1320 cm2 Thru-Put: 10 Liters to 60 Liters

Volumes in your facility will vary with products; however, this should serve as a guideline. The amount and number of active ingredients heavily influence the volume filtered.

Filters with Dual Membrane

This has been a great strategy for our customers. Filters containing dual layers can yield 35% to 2x additional volume filtered. The price increase is approximately 15% for adding a second layer.

Typical Filtered Volumes – Pure Oil Solutions-No Active Ingredients

Filter Size Filter Area Volume to be Filtered
D50C 15.9 cm2 Thru-Put: 25 ml to 495 ml
D65R 26 cm2 Thru-Put: 50 ml to 675 ml
D90R 60 cm2 Thru-Put: 1,215 ml to 1,395 ml
JKP 260 cm2 Thru-Put: 3.6 Liters to 7.2 Liters
MKP 500 cm2 Thru-Put: 8 Liters to 13.5 Liters
SKL-“H" Size 680 cm2 Thru-Put: 12 Liters to 16 Liters
SKL-“S" Size 1320 cm2 Thru-Put: 23 Liters to 33 Liters

Volumes in your facility will vary per oil filtered; however, this should serve as a guideline. For best results, prior to filtering the oil, heat it to 90 to 100 oF, this will allow you to achieve the results shown in the table above.

Oil with Active Ingredients

For oil solutions with one or more active ingredients the filtered volume will reduce approximately 50% or more shown in the table above.



Call Now for a Free Consultation

818-841-2702